Miller Goodall was appointed to assess the potential adverse effects associated with air quality, odour and acoustics that may arise from the construction and operation of the development.

Acoustic Investigation

A comprehensive BS4142 assessment of industrial noise was completed. A noise model was prepared, including embedded acoustic mitigation, which included manufacturing equipment, plant and vehicle movements. No significant effects were found. Recommendations for noise breakout between rooms of the manufacturing plant were provided, and these matters would be dealt in post-approval planning submissions.

Air Quality Investigation

An IAQM construction dust assessment was completed, and dust control mitigation was recommended.

A qualitative screening assessment of vehicular emissions was completed, concluding the levels of generation would have imperceptible changes to air quality.

Odour Investigation

Odour arising from the manufacturing plant processes was concluded as not significant.

An odour impact assessment was requested by United Utilities. The request required an assessment of odour arising from the Fleetwood wastewater treatment works. The purpose was two-fold; to ensure there is no impact to an encroaching business and that operations at the WWTW would not be restricted by the encroachment.

A series of olfactometry odour surveys and multi-tool assessment to IAQM guidance were completed. The findings indicated the commercial use would not be impacted by existing odour, nor would it cause operational restrictions to the existing WWTW.

Action and Outcome

The three assessments demonstrated that there would be no significant impact to surrounding sensitive receptors.

Embedded mitigation from the outset included limiting night-time deliveries, acoustic barriers, and layout placement (office furthest from pollution sources & manufacturing further from sensitive receptors.

What our clients say...

"As is always the case, Miller Goodall professionally respond to every situation and provide a high quality and reliable service."

Richard Lever

Property Capital Plc
"Miller Goodall always provides a consistently high service."

Michelle Bath

Director, DPP Limited
"We engaged Miller Goodall to deal with the noise issues likely to be caused by our new industrial development and to provide a report to the local authority planning department. They were helpful and knowledgeable throughout the course of the scheme, specifying the data required to perform their work and liaising directly with the end user as required to arrange the necessary surveying and monitoring. I would not hesitate to recommend Miller Goodall in the future."

Andrew Laidlaw

The Trustland Group
"Excellence from everyone at Miller Goodall!! I have worked with the team since 2019 and they always demonstrate extensive knowledge on acoustic and air quality matters. They effectively communicate complex concepts and are always proactive in identifying potential risks and suggesting solutions. I would definitely recommend to others."

Richard Dimisianos

Prospect Homes
"Great customer service from start to finish. Quick and got the job done to the required standard."

Martin Fearon

Accrington Stanley Community Trust
“I would like to thank Miller Goodall for all their help throughout this process. Right from our first phone call, we have found your services to be professional, informative and helpful.”

Kieran O’Donnell

Coccion Construction Ltd